Talk to an Expert !
Live chat or (888) 461-1112

V800A1088 : Resideo Honeywell Standing Pilot Gas Valve, 3/4" x 3/4", 24VAC, Standard Opening, Single Stage, 3.5" WC, 1/2" Side Outlet

  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
  • Photo of V800A1088
Resideo Logo
$39124
Special Order - Call for Lead Time

Usually 3 weeks delivery


Please note that Special Order items may be subject to restocking charges or non-returnable. Please visit our Return Policy page for more information.


 

SKU: V800A1088
Compare at: $802.88
You Save: 52%

Resideo Honeywell V800A1088 3/4" x 3/4", 24 Vac, Standard Opening, 3.5" WC, 1/2" Side Outlet, Standing Pilot Gas Valve. This valve is used on gas fired standing pilot appliances with 30 mV thermocouple. These gas controls include a manual gas valve, safety shutoff, single millivoltage automatic operator, pressure regulator, pilot gas filter and flow adjustment, pressure tapping, and thermocouple connector.

Features:
Includes a Q340 Thermocouple, One 3/4" x 1/2" reducer bushing, One 1/2" x 3/8" reducer bushing and a Natural to LP Conversion Kit
Mounting is 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Include pilot flow adjustment screw.
Easy to install, adjust and service; all adjustments and connections are accessible from top of control.
Add separate energy cutoff (ECO) where codes call for dual safety shutoff.
Complete safety shutoff on pilot flame failure.
LITE-RITE (OFF-PILOT-ON) lighting sequence.
ECO connector for V800 models. Part No. 392451-1.(Sold Separately)


Product Specifications

  Approvals, Canadian Standards Association: CSA International: 112395
  Approvals, Underwriters Laboratories Inc.: UL Component Recognized MCCZ2.MH5323
  Body Pattern: Straight-through, multi-tapped with 1/2 in. right and left outlets plugged
  Capacity (kBtuh): At 1 in. wc p.d.-- 335,000 BTU/hr: 34,000 BTU/hr minimum, 425,000 BTU/hr maximum
  Dimensions (in.): 4 3/4 in high x 4 1/16 in. wide x 3 3/16 in. deep
  Dimensions (mm): 121 mm high x 103 mm wide x 81 mm deep
  Electrical Connections: Combination screw and 1/4 in. male quick connects.
  Frequency: 60 Hz
  Inlet/Outlet Size (in.): 3/4 in. NPT x 3/4 in. NPT with 1/2 in. NPT side outlets
  Opening Characteristics: Standard Opening
  Operating Temperature Range (C): 0 C to 79 C
  Operating Temperature Range (F): 32 F to 175 F
  Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
  Pressure Ratings (kPa): 3.5 kPa
  Pressure Ratings (psi): 1/2 psi
  Pressure Regulator: Standard
  Pressure Regulator Setpoint (in. wc): 3.5 in. WC
  Pressure Regulator Setpoint (kPa): 0.87 kPa
  Pressure Tapping: Outlet pressure tap: 1/8 in. NPT with plug
  Type of Fuel: Natural (LP with included conversion kit)
  Voltage: 24 Vac