Talk to an Expert !
Live chat or (888) 461-1112

SV9541Q2561 : Resideo Honeywell SmartValve Gas Valve, Natural Gas/LP, Standard Two-Stage Open, 1/2" x 1/2", for Intermittent Hot Surface Ignition Systems

  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
  • Photo of SV9541Q2561
Resideo Logo
$44245
Special Order - Call for Lead Time

Usually 3 weeks delivery


Please note that Special Order items may be subject to restocking charges or non-returnable. Please visit our Return Policy page for more information.


 

SKU: SV9541Q2561
Compare at: $741.19
You Save: 41%

Resideo Honeywell SV9541Q2561 SmartValve Gas Valve, Nat.Gas/LP, Standard Open, 1/2" x 1/2", 2 Stage, for Intermittent Hot Surface Ignition Systems. The SmartValve® System Controls combine gas flow control and electronic intermittent pilot sequencing functions into a single unit. The Q3450 or Q3480 Pilot hardware supplies the low voltage igniter, flame sensor and pilot burner. These ignition system controls provide all gas ignition safety functions by controlling gas flow, ignition source, and a 120 Vac or 240 Vac combustion air blower. The controls also monitor the appliance airflow proving switch and limit string to assure proper appliance operation, and provide prepurge, postpurge, and timed trial for pilot ignition with 100 percent shutoff and continuous retry. Includes a diagnostic LED indicates system status.

Features:
These controls communicate directly with an electronic fan timer (ST9160 Electronic Fan Timer for single stage applications; ST9162 Electronic Fan Timer for two-stage applications) in typical forced warm air furnace applications.
It can directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.
When controlled directly by a thermostat, these controls do not provide a postpurge function, because power to the control is removed when the thermostat call for heat ends.
The Systems are suitable for a wide range of fan-assisted combustion gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.
Includes a Natural to LP Conversion Kit
Mounting is 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.


Product Specifications

  Ambient Temperature Range (C): -40 C to +79 C
  Ambient Temperature Range (F): -40 F to +175 F
  Body Pattern: Straight-through
  CSA Approved: CSA International: 112395
  Dimensions (in): 3.2 in. wide x 4.9 in. high x 4.1 in.long
  Dimensions (mm): 81 mm wide x124 mm high x 104 mm long.
  Electrical Rating (amp): 24 Vac
  Flame Failure Response Time (sec): 1.6 sec @ 3 µA
  Flame Sense: HSI
  Frequency: 60 Hz
  Ignition Sequence: Intermittent Pilot
  Capacity (ft³/hr): Maximum at 1 in. P.D.--150 ft³/hr; Maximum--200 ft³/hr; Minimum--20 ft³/hr
  Ignition Source: Pilot
  Ignition System Type: Intermittent Hot Surface Pilot Ignition
  Ignition Trials To Lockout: Continuous retry
  Ignition Trial Time (sec): 90 sec
  Inlet/Outlet Size (in): 1/2 in. NPT x 1/2 in. NPT
  Capacity (m³/hr): Maximum at 1 in. P.D.--4.2 m³/hr; Maximum--5.7 m³/hr; Minimum--0.6 m³/hr
  Opening Characteristics: Standard 2-stage
  Pilot Gas Outlet: Yes
  Post Purge: 30 seconds
  PrePurge: 15 seconds
  Pressure Ratings (kPa): 3.5 kPa
  Pressure Ratings (psi): 1/2 psi
  Pressure Regulator Setting (kPa): 0.42 kPa low; 0.80 kPa high
  Pressure Regulator Setting (psi): 1.7 in. WC low; 3.2 in. WC high
  Pressure Tapping: 1/8 in. - NPT
  Type of Gas: Natural/LP