Talk to an Expert !
Live chat or (888) 461-1112

S9200U1000 : Resideo Honeywell S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control

  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
  • Photo of S9200U1000
Resideo Logo
$18899
In-Stock - Ships Immediately


 

SKU: S9200U1000
Compare at: $316.60
You Save: 41%

Resideo Honeywell Universal Hot Surface Ignition Integrated Furnace Control. This Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement.

Features:
Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls.
Main burner ignition using a 120V hot surface igniter.
Flame rectification circuit to monitor flame presence.
Monitoring of system pressure switch, high temperature limit, and rollout functions.
Appliance operation/safety requirements controlled via microprocessor.
Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat.
LED system status, performance and diagnostic indication.
Twinning capability
Used with Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Resideo Honeywell VR8205 recommended.


Product Specifications

  Circulator Load: 14.5FLA / 25LRA max @120Vac
  Cool Fan Off Delay: 0 or 60 seconds
  Cool Fan On Delay: 5 seconds
  Cooling Contacter Used With: Any 24Vac contactor rated at 1.0A or less
  Flame Failure Response Time (sec): 2 Seconds max @ 1µA
  Frequency: 60 Hz
  Heat Off Fan Delay: 60, 90, 120, or 180 Seconds
  Heat On Fan Delay: 30 or 60 seconds
  HSI Warmup Time: 17/27 or 30/30 seconds
  Igniter Current: 5 A resistive @ 120VAC
  Ignition Trials: Three, two tries if flame is not sensed
  Induced Draft Blower Load: 2.2FLA / 25LRA max @120Vac
  Line Volts (V): 120 Vac (97-132 Vac)
  Low Voltage: 24V (18-30 Vac)
  Number of LEDs: 3
  Operating Humidity Range (%RH): 0% to 95% non-condensing
  Operating Temperature Range (C): -40 C to +79 C
  Operating Temperature Range (F): -40 F to +175 F
  Post Purge: 15 seconds
  PrePurge: 30 seconds
  Trial For Ignition: 4, 6, or 8 seconds
  Type of Fan Used With: Standard Induction-Type Circulating Fan

Product Downloads
  Installation Instructions- English

62-24268-01 624557 695-200
85267316149 903106-KIT B003CVV4W2
B071X9DG6S B5-L6VL-2J09 S9200U1000/U
Y0655