S8610U3009 : Resideo Honeywell S8610U3009 Universal Pilot Ignition Module, Used with Intermittent Pilot Assemblies
SKU: | S8610U3009 |
Compare at: | $277.74 |
You Save: | 16% |
Resideo Honeywell S8610U3009 Universal Intermittent Pilot Ignition Module.
Universal intermittent pilot ignition module replaces multiple field installed intermittent pilot modules supplied by Resideo Honeywell, Robertshaw, Johnson, and UTEC (HSC). Uses existing intermittent pilot burner. Includes cross reference, instructions, and accessories for easy replacement.
Includes Damper connection with automatic vent damper plug
Features
Replaces over 400 White-Rodgers, Robertshaw and Resideo Honeywell intermittent pilot ignition modules
Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances
Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed.
For use with Natural or LP gas
For use in single rod or dual rod/remote sense applications
Includes spark cable adapters to allow field replacement of both Resideo Honeywell and competitive controls without replacing existing spark cable.
Dimensions (in.)3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
Dimensions (mm)100 mm high x 138 mm wide x 67 mm deep
Approvals, Canadian Standards Association Design Certified
Product Specifications
5 minute delay after failed trial for ignition. | |
2 seconds maximum | |
Single Rod or Two Rods | |
60Hz | |
Continuous Retry | |
Internal high voltage spark generator | |
Continuous Retry | |
15 or 90 sec | |
Intermittent Pilot | |
Configurable to 30 seconds or no prepurge | |
-40 F to +165 F | |
Natural or LP | |
24Vac |
Product Downloads
Product Specifications
Installation Instructions- English